Overheating Protection Activated
The F15 error code means your Miele dryer's safety thermostat has detected an internal temperature that exceeds the safe operating limit. The machine immediately shuts down the heater and may stop the cycle.
~50%
DIY Fixable
$100-400
Typical Repair Cost
20 min – 2 hrs
Pro Repair Time
Quick Assessment
Answer to continue safely
Is it safe to keep using?
No. Overheating is a fire risk. Do not use the dryer until the cause of overheating is identified and resolved. Clean all airflow components first.
Can I reset the code?
Yes. Yes — but only after the machine has cooled and airflow has been cleaned. The thermal protection needs to reset naturally.
When to stop immediately?
Stop if you notice: Burning smell, Scorch marks on lint.
Symptoms You May Notice
Dryer shuts down mid-cycle
The machine stops abruptly during a heated cycle
Exterior is very hot
The machine body feels unusually hot
Burning smell possible
Overheated lint may produce a scorching smell
F15 after extended running
The code appears after the machine has been running and heat has accumulated
Possible Causes
Blocked Exhaust/Condenser
The #1 cause — hot air cannot escape, so internal temperature rises.
DIY PossibleClogged Lint Filter
Lint buildup restricts airflow.
DIY PossibleFailed Cooling Fan (Heat Pump Models)
The fan that cools the heat pump has failed.
Requires ProfessionalFaulty Thermostat
The thermostat triggers at too low a temperature (false alarm).
Requires ProfessionalHeater Not Cycling Off
The heater control is not cycling off at the set temperature.
Requires ProfessionalSafe Checks You Can Do
-
1
Clean Lint Filter
Remove and thoroughly clean the lint filter.
This should be done before every cycle.
-
2
Clean Exhaust/Condenser
Clean the exhaust vent (vented models) or condenser unit (condenser/heat pump models).
A clean airflow path is the best defense against overheating.
-
3
Let Machine Cool
Wait at least 30 minutes for the machine to cool completely before attempting to restart.
The thermal protection needs time to reset.
-
4
Power Reset After Cooling
Turn off at mains for 10 minutes after the machine has cooled.
Some thermal protectors auto-reset; others require power cycling.
-
5
Test on Low Heat
After cooling and cleaning, run a cycle on the lowest heat setting as a test.
If it completes without F15, gradually try higher settings.
When to Call a Professional
Contact a qualified Miele technician if:
- All airflow paths clean but F15 persists
- Thermostat failed
- Heater not cycling off
- Heat pump cooling fan failed
- Under warranty
Need Professional Help?
Find qualified Miele technicians in your area for proper diagnostics and repair.
Schedule Appointment