NTC Temperature Sensor Fault
The F01 error code means the NTC temperature sensor in your Miele dryer is sending readings outside the expected range. The control board cannot verify the drum temperature, so it stops the heating process.
~25%
DIY Fixable
$150-350
Typical Repair Cost
45 min – 1.5 hrs
Pro Repair Time
Quick Assessment
Answer to continue safely
Is it safe to keep using?
No. Without temperature monitoring, the dryer cannot control heating safely. Do not use until F01 is resolved.
Can I reset the code?
Yes. Yes. Turn off for 10 minutes. If caused by a lint-covered sensor, cleaning may resolve it.
When to stop immediately?
Stop if you notice: F01 returns after cleaning and reset, No heat at all.
Symptoms You May Notice
Dryer does not heat
The drum spins but no warm air is produced
Clothes come out damp
Without heat, items do not dry
Cycle runs but never finishes
The machine waits for a temperature it cannot detect
F01 appears mid-cycle
Triggers during the heating phase
Possible Causes
Failed NTC Sensor
The thermistor has drifted or developed an open/short circuit.
Requires ProfessionalLoose Sensor Connector
Vibration has loosened the wiring plug.
Requires ProfessionalDamaged Wiring
Heat or abrasion damaged the sensor wires.
Requires ProfessionalLint Coating on Sensor
Heavy lint buildup insulates the sensor.
DIY PossibleControl Board Input Fault
The sensor input circuit on the PCB has failed.
Requires ProfessionalSafe Checks You Can Do
-
1
Clean the Lint Filter
Remove and clean the lint filter thoroughly. Check the filter housing for lint buildup that may affect nearby sensors.
The lint filter should be cleaned before every cycle.
-
2
Power Reset
Turn off at mains for 10 minutes.
A longer reset helps sensor circuits recalibrate.
-
3
Clean the Condenser (Heat Pump Models)
If your dryer has a condenser unit, remove and rinse it. Lint coating on the condenser can affect temperature readings.
Rinse under running water until clear.
-
4
Run a Short Program
After reset, run a short timed dry. Check if warm air comes out.
If heat returns, monitor for recurrence.
-
5
Check Exhaust (Vented Models)
Ensure the exhaust vent is not blocked. Restricted airflow can cause abnormal temperature readings.
Disconnect and check the full vent length.
When to Call a Professional
Contact a qualified Miele technician if:
- Sensor reads open or short circuit
- F01 persists after cleaning
- Wiring visibly damaged
- Under warranty
Need Professional Help?
Find qualified Miele technicians in your area for proper diagnostics and repair.
Schedule Appointment